Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideA Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ProductsIntel
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide xiiiTable of ContentsSafety Information ...
82 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing the Power Supply (SR1630HGPRX)Caution: The power supply is NOT hot-swappable. B
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 835. Insert the replacement power supply at an angle into the server system, sliding the po
84 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing the Front Panel Board (SR1630GPRX)Caution: The front panel is NOT hot-swappable
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 858. Insert the replacement front panel board into the server system over the two standoffs
86 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing the Front Panel Board (SR1630HGPRX)Caution: The front panel is NOT hot-swappabl
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 877. Remove the light pipes from the front panel board by lifting straight up (see letters
88 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 70. Installing Front Panel Board into the Server System (SR1630HGPRX)ABCAF003385
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 8910. Install the light pipes on the front panel board as shown in Figure 71. Install the l
90 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing a System Fan (SR1630GPRX)Caution: The fans are NOT hot-swappable. Before removi
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 916. Remove the three screws that hold the fan bracket in place. Save these screws. You wil
xiv Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideRecovering the BIOS ...
92 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide9. Turn the bracket over and remove the two screws that attach the failed fan to the brac
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 9314. Connect the fans to the server board. See letters “A” and “B” in Figure 75.Figure 75.
94 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing a System Fan (SR1630HGPRX)Caution: The fans are NOT hot-swappable. Before remov
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 957. Lift the fan from the system (see letter “C” in Figure 76).Figure 76. Removing Fan fro
96 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 77. Installing Fan into the Server System (SR1630HGPRX)11. Install the server syst
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 97Figure 78. Installing the Rack Handle4. Repeat Step 3 on the opposite side of the server.
98 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideRemoving the Rack Handles1. Observe the safety and ESD precautions at the beginning of th
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 99Appendix A: Technical ReferenceCable RoutingWhen you add or remove components from your s
100 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideCable Routing (SR1630GPRX)Figure 80. Data Cable Routing (SR1630GPRX)SATAHDD 0HDD 1Optica
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 101Cable Routing (SR1630HGPRX)Figure 81. Cable Routing (SR1630HGPRX)Server BoardPower Suppl
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide xvInstalling and Removing the I/O Expansion Module ...
102 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide350-W Single Power Supply Input Voltages• 100 - 127 V at 50 / 60 Hz 6.0 A• 200 - 240 V a
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 103System Environmental SpecificationsTable 8. System Environmental SpecificationsTemperatu
104 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 105Appendix B: TroubleshootingThis chapter helps you identify and solve problems that might
106 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideProblems following Initial System InstallationProblems that occur at initial system star
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 107Caution: Turn off devices before disconnecting cables: Before disconnecting any peripher
108 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide• CD-ROM drive activity light does not light.• There are problems with application softw
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 109• Is the onboard video controller enabled in the BIOS?• Remove all add-in cards and see
110 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide• Have any of the fan motors stopped? Use the server management subsystem to check the f
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 111• If you are directly connecting two servers (without a hub), you will need a crossover
xvi Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideProblems with Network ...
112 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideProblems with Newly Installed Application SoftwareProblems that occur when you run new a
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 113Devices are not Recognized under Device Manager (Microsoft Windows* Operating System)The
114 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideLED InformationThe Intel® Server System SR1630GP / SR1630HGP includes LEDs that can aid
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 115Appendix C: Installation/Assembly Safety InstructionsEnglishThe power supply in this pro
116 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideAfter you have completed the six SAFETY steps above, you can remove the system covers. T
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 117DeutschThe system is designed to operate in a typical office environment. Choose a site
118 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideSICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminner
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 119FrançaisDer Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System i
120 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideNe pas essayer d'utiliser ni modifier le câble d'alimentation CA fourni, s&apo
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 121Afin de permettre le refroidissement et l'aération du système, réinstallez toujours
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide xviiAlimentation et avertissements en matière d’électricité ...
122 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideEspañolEl usuario debe abstenerse de manipular los componentes de la fuente de alimentac
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 123Después de completar las seis instrucciones de SEGURIDAD mencionadas, ya puede extraer l
124 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideEl sistema está diseñado para funcionar en un entorno de trabajo normal. Escoja un lugar
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 125ItalianoRivolgersi ad un tecnico specializzato per la riparazione dei componenti dell&ap
126 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuidePer il giusto flusso dell'aria e raffreddamento del sistema, rimettere sempre le co
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 127Appendix D: Safety InformationEnglishServer Safety InformationThis document applies to I
128 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideIntended Application UsesThis product was evaluated as Information Technology Equipment
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 129• Conform to local occupational health and safety requirements when moving and lifting e
130 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide• Do not access the inside of the power supply. There are no serviceable parts in the p
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 131For proper cooling and airflow, operate the chassis only with the chassis covers install
xviii Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
132 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideSicherheitshinweise und VorsichtsmaßnahmenUm Verletzungen und Beschädigungen zu vermeide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 133StandortauswahlDas System ist für den Betrieb innerhalb normaler Büroumgebungen geeignet
134 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideWarnungen zu Netzspannung und ElektrizitätVorsicht: Durch Betätigen der mit dem Standby-
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 135• Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten e
136 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideAndere GefahrenBatterieaustauschVorsicht: Wird die Batterie unsachgemäß ausgetauscht, be
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 137FrançaisConsignes de sécurité sur le serveurCe document s’applique aux cartes serveur In
138 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideDomaines d’utilisation prévusCe produit a été testé comme équipement informatique (ITE)
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 139• Équipé d’un espace suffisant pour accéder aux cordons d’alimentation secteur, car ils
140 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideAlimentation et avertissements en matière d’électricitéAttention: Le bouton d’alimentati
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 141Attention: Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur insta
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide xixList of FiguresFigure 1. Intel® Server System SR1630GPRX ...
142 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide• Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 143Aplicaciones y usos previstosEste producto ha sido evaluado como equipo de tecnología in
144 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideSelección de la ubicaciónEl sistema se ha diseñado para funcionar en un entorno normal d
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 145trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje. No in
146 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guidede conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de co
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 147• Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto.Periféricos
148 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 149
150 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide预期应用使用 根据评估,本产品为信息技术设备 (ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE 应用的其他产品种类和环境(如医疗、工业、住宅、报
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 151为避免电击,请在打开服务器之前,关闭服务器并断开服务器上连接的电源线、电信系统、网络和调制解调器。 电源线警告 如果产品未提供交流电线,请购买一根您所在国家批准使用的交流电线
xx Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 43. Attaching the Optical Drive to the Attachment Bracket...
152 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 153冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行系统可能导致系统部件受损。
154 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 155Appendix E: Regulatory and Compliance InformationProduct Regulatory ComplianceWarning: T
156 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideProduct Safety ComplianceThe server system complies with the following product safety re
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 157Product Ecology RequirementsIntel has a system in place to restrict the use of banned su
158 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide— UL, cUL Recognition (Canada / USA)— CNCA Certification (China)— CE DOC (Europe)— CB Ce
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 159• Plastics— Require being UL Recognized and suitable flammability requirement for its ap
160 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideTable 12. .Product Regulatory Compliance MarkingsRegulatory Compliance Region MarkingIRA
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 161BSMI Mark Tai wa nR33025UL Mark USA / CanadaFCC Mark USA (FCC Mark)This device complies
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide xxiList of TablesTable 1. Intel® Server System SR1630GPRX/SR1630HGPRX Feature Summary ...
162 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideMultiple Power Cord Multiple Power CordEnglish: This unit has more than one power supply
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 163Other Recycling Package MarksWill be added on Package label.Lithium Perchlorate insert C
164 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideElectromagnetic Compatibility NoticesFCC Verification Statement (USA)This device complie
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 165Industry Canada (ICES-003)Cet appareil numérique respecte les limites bruits radioélectr
166 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideBSMI (Taiwan)The BSMI Certification Marking and EMC warning is located on the outside re
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 167Appendix F: WarrantyLimited Warranty for Intel® Chassis Subassembly ProductsIntel warran
168 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideThis Limited Warranty does not cover damages due to external causes, including accident,
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 169How to Obtain Warranty ServiceTo obtain warranty service for this Product, you may conta
170 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 171Appendix G: Getting HelpWorld Wide Webhttp://www.intel.com/support/motherboards/server/S
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 11 Server System FeaturesThis chapter briefly describes the main features of the server sys
172 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideIn Asia-Pacific regionAustralia... 1800 649931Cambodia.. 63 2 636 9797 (via Philippines
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 173Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481Co
ii Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideDisclaimer Information in this document is provided in connection with Intel® products. N
2 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 2. Intel® Server System SR1630HGPRXNote: Figure 2 is shown with an optional optical
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 3Table 1 summarizes the features of the server system.Table 1. Intel® Server System SR1630G
4 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideI/O Control External connections:• DB-15 video connectors• RJ45 type serial Port A connect
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 5LAN One Gigabit Ethernet device 82574L connect to PCI-E x1 interfaces on the PCH.Two Gigab
6 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideChassis Component IdentificationThis section helps you identify the components of your ser
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 7System Status (on standby power)Green On Running / normal operationBlink System ready, but
8 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideSystem Front Panel (SR1630HGPRX)The front of the server system includes the following butt
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 9System RearFigure 5. Back Panel ConnectorsThe NIC LEDs on the NIC connector are marked as
10 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideB N/A Off 10 Mbit / sec data rate is selectedGreen On 100 Mbit / sec data is selectedYell
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 11Peripheral Devices (SR1630GPRX)The server system provides locations and hardware for inst
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide iiiSafety InformationImportant Safety InstructionsRead all caution and safety statements in
12 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideSlimline Optical Drive CarrierOne slimline drive carrier is included with your server sys
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 13Internal Components (SR1630GPRX)Figure 6. System Components (SR1630GPRX)BCDEFHGAIAJKAF003
14 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInternal Components (SR1630HGPRX)Figure 7. System Components (SR1630HGPRX)BACDEFGKJMLHIAA
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 15Server Board Connectors / Components
16 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 8. S3420GPRX Connector and Component LocationsA. Dual Intel® I/O Expansion Module
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 17Configuration JumpersFigure 9. Configuration Jumper DescriptionsME ForceUpdateJ1F1Disable
18 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideHardware RequirementsTo avoid integration difficulties and possible board damage, your sy
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 19The Independent Channel Mode is the default Maximum Performance Mode preferred for Intel®
20 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 212 Server UtilitiesUsing the BIOS Setup UtilityThis section describes the BIOS Setup Utili
iv Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide䞡㽕ᅝܼᣛᇐ
22 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide“Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus.
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 23Upgrading the BIOSThe upgrade utility allows you to upgrade the BIOS in flash memory. The
24 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideObtaining the UpgradeDownload the BIOS image file to a temporary folder on your hard driv
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 25Figure 10. BIOS Recovery Jumper3. Insert the bootable BIOS Recovery media containing the
26 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide2. Open the server chassis.3. Move the jumper from the normal operation position, Passwor
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 27Figure 12. CMOS Recovery Jumper4. Wait five seconds.5. Move the jumper back to default po
28 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guideboard provides an Integrated BMC Force Update jumper, which forces the Integrated BMC int
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 293 Hardware Installations and UpgradesCaution: No components in the Intel® Server System S
30 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideRemoving and Installing the Server CoverRemoving the Server System CoverYou must operate
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 317. SR1630HGPRX: Remove the four screws at the front of the chassis. See letter “A” in Fig
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide vWarningsHeed safety instructions: Before working with your server product, whether you are
32 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInstalling the Server System Cover1. Observe the safety and ESD precautions at the beginn
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 33Figure 17. Installing the Server System Cover (SR1630HGPRX)7. Reconnect all peripheral de
34 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 18. Removing the Processor Air Duct (SR1630GPRX)Figure 19. Removing the Processor
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 35Installing the Processor Air Duct1. Observe the safety and ESD precautions at the beginni
36 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 21. Installing the Processor Air Duct (SR1630HGPRX)Installing and Removing MemoryC
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 37Installing DIMMsTo install DIMMs, follow these steps:1. Observe the safety and ESD precau
38 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide2. Power down the server and unplug all peripheral devices and the AC power cable.3. Remo
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 39Replacing the ProcessorNote: This manual assumes a processor is already installed and you
40 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInstalling the ProcessorTo install a processor, follow these instructions: 1. Observe the
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 41Figure 24. Opening the Load PlateCaution: Do not touch the socket pins; they are very sen
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide viiPrefaceAbout this ManualThank you for purchasing and using the Intel® Server System SR16
42 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide7. Orient the processor with the socket so the processor cutouts match the socket notches
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 4310. Lower the CPU load plate.11. Lower the socket lever.12. Install the heat sink. For in
44 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide6. Reinstall and reconnect any parts you removed or disconnected to reach the processor s
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 45Figure 29. Removing Drive Carrier from the Server System (SR1630GPRX)AF001050BAChassis Fr
46 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide8. Position the drive with the drive connectors facing up as shown in Figure 30.9. Set th
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 4714. HDD1 only: Route the power cable into the cable clip on the top of the hard drive bra
48 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 32. Connecting Hard Drive Power and Data Cables (SR1630GPRX)17. Install the server
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 494. Disconnect the power and data cables from the drive.5. HDD1 location only: Slide the p
50 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide11. Set the drive assembly into place in the chassis.12. Attach the drive assembly to the
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 51Installing and Removing a Hot-Swap SATA Drive (SR1630HGPRX)You can install up to three ho
viii Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideProduct ContentsThe Intel® Server System SR1630GPRX/SR1630HGPRX ships with the Intel® S
52 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide2. Open the latch at the front of the hard drive carrier. See letter "A" in Fig
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 539. With the black lever in the fully open position, slide the drive assembly into the ser
54 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide8. Install the server system cover. For instructions, see “Installing the Server System C
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 555. Attach the optical drive to the brackets, using the four screws as shown in Figure 39.
56 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide10. Install the server system cover. For instructions, see “Installing the Server System
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 57Figure 42. Removing the Optical Drive Brackets8. If you are installing a replacement opti
58 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide3. Remove the server system cover. For instructions, see “Removing the Server System Cove
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 59Removing a Slimline Optical Drive (SR1630HGPRX)1. Observe the safety and ESD precautions
60 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInstalling and Removing the PCIe* Riser AssemblyCaution: The PCIe* riser assembly is NOT
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 616. If you need to add or replace a PCIe* Riser connector, see “Installing or Replacing a
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide ixIntel® Server System SR1630HGPRX ContentsYour Intel® Server System SR1630HGPRX ships with
62 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide5. Install the server system cover. For instructions, see “Installing the Server System C
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 638. Install the replacement riser connector, if desired. For instructions, see “Installing
64 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide12. Install the server system cover. For instructions, see “Installing the Server System
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 655. Remove the screw at the rear of the riser assembly. See letter “A” in Figure 51. Save
66 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide5. Remove the screw at the rear of the riser assembly. See letter “A” in Figure 52. Save
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 67Installing and Removing the I/O Expansion ModuleInstalling the I/O Expansion Module1. Rem
68 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideFigure 53. Installing the I/O Expansion Module to the Server System7. Install the process
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 69Figure 54. Removing the I/O Expansion Module from the Server System6. Install the process
70 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInstalling and Removing the RMM3 LiteInstalling the RMM3 Lite1. Remove the PCI riser asse
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 71Figure 56. Removing the RMM3 Lite to the Server System3. Install the PCI riser assembly i
x Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideServer System ReferencesIf you need more information about this product or information abo
72 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideReplacing the Server BoardRemoving the Server Board1. Observe the safety and ESD precauti
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 739. Remove the nine screws from the server board (see letter “A”) and lift the server boar
74 Intel® Server System SR1630GPRX/SR1630HGPRX Service GuideInstalling the Server Board1. Observe the safety and ESD precautions at the beginning of
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 758. Install the processor and the heat sink. For instructions, see “Installing the Process
76 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Info
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 77Replacing the Power Supply (SR1630GPRX)Caution: The power supply is NOT hot-swappable. Be
78 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide.Figure 60. Disconnecting Power Cables (SR1630GPRX)HDD 0HDD 1Optical DeviceADGCECPUFLAGCP
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 795. Remove the screw at the back of the server system, next to the AC power input. Save th
80 Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide7. Insert the replacement power supply at an angle into the server system, sliding the po
Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide 819. Connect the power supply cables to the server board and peripherals. See Figure 63.— A