A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D69842-003

Fichier PDF · ·

Imprimer

Imprimer le document

Partage

Résumé du contenu

Page 1 - User’s Guide

® Server System SR2520SA User’s Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number…

Page 2

ii Intel ® Server System SR2520SA User’s Guide Disclaimer Information in this document is provided in connection with Intel® products. No license…

Page 3

® Server System SR2520SA User’s Guide iii

Page 4

iv Intel ® Server System SR2520SA User’s Guide §

Page 5 - Product Contents

Preface About this Manual Thank you for purchasing and using the Intel ® Server System SR2520SA. This manual is written for system technicians who are…

Page 6

vi Intel ® Server System SR2520SA User’s Guide There are three versions of this server system: the Intel ® Server Systems SR2520SAX/ SR2520SAXS and…

Page 7

® Server System SR2520SA User’s Guide vii Intel ® Server System SR2520SAXS/SR2520SAXSR Contents Your Intel ® Server System SR2520SAXS/SR2520SAXSR…

Page 8

viii Intel ® Server System SR2520SA User’s Guide Intel ® Server System SR2520SAF/SR2520SAFR Contents Your Intel ® Server System SR2520SAF/SR2520SAFR…

Page 9 - Safety Information

Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions.…

Page 10 - 服务器主板与服务器机箱安全信息》)。

x Intel ® Server System SR2520SA User’s Guide 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010…

Page 11 - Warnings

® Server System SR2520SA User’s Guide xi Warnings Heed safety instructions: Before working with your server product, whether you are using this guide…

Page 12

xii Intel ®

Page 13 - Table of Contents

® Server System SR2520SA User’s Guide xiii Table of Contents Preface v About this Manual v Manual Organization v Product Contents v Intel ® Server…

Page 14

xiv Intel ® Server System SR2520SA User’s Guide Removing the System Cover 26 Installing the System Cover 27 Removing and Installing the Processor Air…

Page 15

® Server System SR2520SA User’s Guide xv Preparing for the Upgrade 67 Upgrading the BIOS 68 Clearing the Password 68 Clearing the CMOS 69 Appendix A…

Page 16

xvi Intel ® Server System SR2520SA User’s Guide Specific Problems and Corrective Actions 99 Power Light Does Not Light 100 No Characters Appear on…

Page 17

® Server System SR2520SA User’s Guide xvii Warnhinweise für den Systemzugang 127 Warnhinweise für Racks 127 Elektrostatische Entladungen (ESD) 128…

Page 18

xviii Intel ®

Page 19 - List of Figures

® Server System SR2520SA User’s Guide xix List of Figures Figure 1. Intel ® Server System SR2520SA 3 Figure 2. ChassisComponents (SR2520SAX/SR2520SAXS…

Page 20

xx Intel ® Server System SR2520SA User’s Guide Figure 34. Installing Optical Drive and Drive Bracket into Server System 46 Figure 35. Removing Drive…

Page 21 - List of Tables

® Server System SR2520SA User’s Guide xxi List of Tables Table 1. Server System References 1 Table 2. Intel ® Server System SR2520SA Feature Summary 4…

Page 22

xxii Intel ®

Page 23 - 1 Server System References

1 Server System References If you need more information about this product or information about the accessories that can be used with this server…

Page 24

® Server System SR2520SA User’s Guide Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product Tested…

Page 25 - 2 Server System Features

2 Server System Features This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a…

Page 26 - Table 2. Intel

® Server System SR2520SA User’s Guide Table 2 summarizes the features of the server system. Table 2. Intel ® Server System SR2520SA Feature Summary…

Page 27

® Server System SR2520SA User’s Guide 5 Peripheral Interfaces External connections: • Stacked PS/2* ports for keyboard and mouse • DB9 Serial A port •…

Page 28 - • Three system cooling fans

® Server System SR2520SA User’s Guide Power Supply • Single 600 W power supply module (SR2520SAF) • Redundant 600 W power supply modules (SR2520SAX/…

Page 29 - Internal Components

® Server System SR2520SA User’s Guide 7 Chassis Component Identification This section helps you identify the components of your server system. If you…

Page 30

® Server System SR2520SA User’s Guide Figure 3. ChassisComponents (SR2520SAF/SR2520SAFR) A. Rack Handles G. Front Panel B. System Cooling Fans H.…

Afficher les 164 pages
Page 31 - Locations

® Server System SR2520SA User’s Guide 9 Server Board Connector and Component Locations Figure 4. Server Board Connector and Component Locations…

Page 32 - Configuration Jumpers

® Server System SR2520SA User’s Guide Configuration Jumpers Figure 5. BIOS Select Jumper NN. Backplane Connector B OO. Front Panel Header PP.…

Page 33 - Figure 6. Recovery Jumpers

® Server System SR2520SA User’s Guide 11 Figure 6. Recovery Jumpers Jumper Name Jumper Purpose CMOS Clear If pins 2-3 are jumpered, the CMOS settings…

Page 34

® Server System SR2520SA User’s Guide Intel ® Light Guided Diagnostics (SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR Only) The server board…

Page 35 - Back Panel Connectors

® Server System SR2520SA User’s Guide 13 Back Panel Connectors Figure 8. Intel ® Server System SR2520SAF/SR2520SAFR Back Panel Connectors Figure 9.…

Page 36 - Hot-Swap Backplane

® Server System SR2520SA User’s Guide The NIC LEDs at the right and left of each NIC provide the following information. Hot-Swap Backplane The Intel ®…

Page 37 - RAID Support

® Server System SR2520SA User’s Guide 15 RAID Support The Intel ® Server System SR2520SA is available in both fixed and redundant models. The fixed…

Page 38

® Server System SR2520SA User’s Guide SAS In addition to the SATA features described above, the Intel ® Server System SR2520SAXS/SR2520SAXSR also has…

Page 39 - Front of Server System

® Server System SR2520SA User’s Guide 17 Front of Server System Control Panel The diagram below shows the features available on the control panel. .…

Page 40 - Peripheral Devices

® Server System SR2520SA User’s Guide Bezels The optional front bezel provides a snap-on design that allows for maximum airflow through the server…

Page 41 - Rack-Mounted Systems

® Server System SR2520SA User’s Guide 19 Hard Disk Drives The server system ships with six drive carriers for installing six SAS or Serial ATA (SATA)…

Page 43 - 3 Hardware Installations and

3 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the “Safety Information” at the…

Page 44

® Server System SR2520SA User’s Guide Fixed Bracket Rack Mount Installation 1. Fully extend a rail assembly; the finger tab for the extension lock is…

Page 45 - Basic Rail Rack Mount Removal

® Server System SR2520SA User’s Guide 23 22. Fully extend the left and right rails until the extension locks have engaged and the rails will not push…

Page 46

® Server System SR2520SA User’s Guide 11. Slide the server chassis all the way into the rack. 12. Use the rack screws (#10-32 x 3/4) to secure the…

Page 47 - Removing the Front Bezel

® Server System SR2520SA User’s Guide 25 Removing the Front Bezel Use the steps below if your system includes a front bezel. 1. Unlock the bezel. 2.…

Page 48 - Removing the System Cover

® Server System SR2520SA User’s Guide Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the…

Page 49 - Installing the System Cover

® Server System SR2520SA User’s Guide 27 4. Remove the top cover screws. See letter "A" in the figure below. 5. While holding in the blue button at…

Page 50

® Server System SR2520SA User’s Guide Figure 18. Installing the Server System Cover Removing and Installing the Processor Air Duct Always operate your…

Page 51

® Server System SR2520SA User’s Guide 29 Figure 19. Removing the Processor Air Duct

Page 52

® Server System SR2520SA User’s Guide Installing the Processor Air Duct 1. Observe the safety and ESD precautions at the beginning of this book. See…

Page 53 - Installing DIMMs

® Server System SR2520SA User’s Guide 31 Installing and Removing Memory The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1…

Page 54

® Server System SR2520SA User’s Guide Figure 21. Installing the Memory 6. Make sure the clips at either end of the DIMM socket(s) are pushed outward…

Page 55 - Installing the Processor

® Server System SR2520SA User’s Guide 33 11. Replace the system's cover and reconnect the AC power cord(s). For instructions on installing the…

Page 56

® Server System SR2520SA User’s Guide 4. Remove the system's cover. For instructions, see “Removing the System Cover”. 5. Remove the processor air…

Page 57 - Installing the Heat Sink(s)

® Server System SR2520SA User’s Guide 35 10. Remove the protective socket cover (see Figure 24). Note: Retain the protective socket cover for use when…

Page 58 - Removing a Processor

® Server System SR2520SA User’s Guide Figure 25. Installing the Heat Sink (2U Passive Heat Sink Shown) 4. Reinstall and reconnect any parts you…

Page 59 - SR2520SAXSR)

® Server System SR2520SA User’s Guide 37 9. Raise the CPU load plate. 10. Remove the processor. 11. If installing a replacement processor, see…

Page 60

® Server System SR2520SA User’s Guide Figure 26. Removing Hot-swap Disk Carrier from the Server System (SR2520SAX/SR2520SAXS and…

Page 61

® Server System SR2520SA User’s Guide 39 4. Remove the four screws that attach the plastic retention device or the previously installed hard drive to…

Page 62

® Server System SR2520SA User’s Guide Figure 28. Install Drive Assemby into the Server System (SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR) 11.…

Page 63 - (SR2520SAF/SR2520SAFR)

® Server System SR2520SA User’s Guide 41 Removing a SAS or SATA Hot-swap Hard Disk Drive (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) 1. Remove…

Page 64

® Server System SR2520SA User’s Guide 2. Remove the four screws securing the hard drive bracket in place (see letter “A” in the figure below). Save…

Page 65 - SR2520SAFR)

® Server System SR2520SA User’s Guide 43 Removing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the server system cover. 2. Remove the…

Page 66 - Installing the Optical Drive

® Server System SR2520SA User’s Guide Installing or Removing the Optical Drive Cautions:The optical drive is NOT hot swappable. Before removing or…

Page 67

® Server System SR2520SA User’s Guide 45 7. Install the optical drive to the drive bracket (see letter “A” in the figure below) and secure it with…

Page 68 - Removing the Optical Drive

® Server System SR2520SA User’s Guide Figure 34. Installing Optical Drive and Drive Bracket into Server System 11. Reinstall the front panel board.…

Page 69

® Server System SR2520SA User’s Guide 47 Figure 35. Removing Drive Bracket and Optical Drive from the Server System 7. Remove the screws securing the…

Page 70 - Installing a PCI Add-in Card

® Server System SR2520SA User’s Guide Installing and Removing a PCI Add-in Card The instructions below describe how to install and remove a PCI add-in…

Page 71 - Removing a PCI Add-in Card

® Server System SR2520SA User’s Guide 49 9. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 10. Install the…

Page 72 - Installing the Server Board

® Server System SR2520SA User’s Guide Installing and Removing the Server Board Installing the Server Board 1. Observe the safety and ESD precautions…

Page 73 - Removing the Server Board

® Server System SR2520SA User’s Guide 51 7. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 8. Install the…

Page 74 - Replacing the Backup Battery

® Server System SR2520SA User’s Guide 6. Install the replacement server board. For instructions, see “Installing the Server Board”. 7. Install the…

Page 75

® Server System SR2520SA User’s Guide 53 1. Observe the safety and ESD precautions in “Safety Information”. 2. Turn off all peripheral devices…

Page 76

® Server System SR2520SA User’s Guide Replacing the Redundant Power Supply (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) Caution: The power…

Page 77

® Server System SR2520SA User’s Guide 55 5. Insert the replacement power supply module into the power supply cage until it clicks into place. Figure…

Page 78

® Server System SR2520SA User’s Guide Figure 44. Removing Power Supply Module from the Server System (SR2520SAF/SR2520SAFR) 7. Slide the replacement…

Page 79

® Server System SR2520SA User’s Guide 57 Figure 45. Installing Power Supply Module into the Server System (SR2520SAF/SR2520SAFR) 10. Install the…

Page 80

® Server System SR2520SA User’s Guide 4. Remove the server system cover. For instructions, see “Removing the System Cover”. 5. Remove the screw…

Page 81

® Server System SR2520SA User’s Guide 59 8. Lower the replacement front panel board into the server system (see letter “A”) and slide it forward (see…

Page 82 - Replacing a System Fan

® Server System SR2520SA User’s Guide Replacing a System Fan Caution: The system fans are NOT hot swappable. Before removing or replacing a fan, you…

Page 83

® Server System SR2520SA User’s Guide 61 Figure 51. Removing a Fan from the Fan Module 7. Position the replacement fan so the connector on the fan is…

Page 84 - Installing the Rack Handles

® Server System SR2520SA User’s Guide Figure 53. Installing the Fan Module 11. Install the server system cover. For instructions, see “Installing the…

Page 85 - Removing the Rack Handles

® Server System SR2520SA User’s Guide 63 Figure 54. Installing the Rack Handle 5. Install the front bezel. For instructions, see “Installing the Front…

Page 86

® Server System SR2520SA User’s Guide Figure 55. Removing the Rack Handle 5. Plug all peripheral devices and the AC power cable(s) into the server.

Page 87 - 4 Server Utilities

4 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration…

Page 88 - Table 4. Setup Menu Key Use

® Server System SR2520SA User’s Guide “Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu…

Page 89 - Upgrading the BIOS

® Server System SR2520SA User’s Guide 67 Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in…

Page 90 - Clearing the Password

® Server System SR2520SA User’s Guide Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive. See “Server System…

Page 91 - Clearing the CMOS

® Server System SR2520SA User’s Guide 69 4. Wait five seconds. 5. Return the Password Clear jumper to the Password Clear Protect position, covering…

Page 93 - (Auxiliary

Appendix A: Technical Reference Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) When you add or remove components from your server…

Page 94

® Server System SR2520SA User’s Guide Cable Routing (SR2520SAF/SR2520SAFR) When you add or remove components from your server system, make sure your…

Page 95

® Server System SR2520SA User’s Guide 73 600W Single Power Supply Input Voltages • 100-127V at 50/60 Hz; 8.55 A max. • 200-240V at 50/60 Hz; 4.3 A…

Page 96

® Server System SR2520SA User’s Guide System Environmental Specifications Table 6. System Environmental Specifications Temperature Non-operating…

Page 97 - SR2520SAXSR Only)

Appendix B: LED Decoder (SR2520SAX /SR2520SAXS and SR2520SAXR/ SR2520SAXSR Only) During the system boot process, BIOS executes a number of platform…

Page 98

® Server System SR2520SA User’s Guide Table 8. Diagnostic LED POST Code Decoder Checkpoint Diagnostic LED Decoder Description G=Green, R=Red, A=Amber…

Page 99

® Server System SR2520SA User’s Guide 77 PCI Bus 0x50h OFF R OFF R Enumerating PCI busses 0x51h OFF R OFF A Allocating resources to PCI busses 0x52h…

Page 100

® Server System SR2520SA User’s Guide 0x93h R OFF G A Enabling the keyboard 0x94h R G OFF R Clearing keyboard input buffer 0x95h R G OFF A Instructing…

Page 101

® Server System SR2520SA User’s Guide 79 0XDA A R G R Trying boot device selection 0xDB A R G A Trying boot device selection 0xDC A A OFF R Trying…

Page 102

® Server System SR2520SA User’s Guide 0xFAh A R A R Operating system has requested the system to reset (ResetSystem () has been called) Pre-EFI…

Page 103 - Appendix C: Getting Help

Appendix C: Getting Help World Wide Web http://support.intel.com/support/motherboards/server/s5000vsa. Telephone All calls are billed per incident…

Page 104 - Latin America

® Server System SR2520SA User’s Guide In Asia-Pacific region Australia 1800 649931 Cambodia.. 63 2 636 9797 (via Philippines) China 800 820 1100…

Page 105

® Server System SR2520SA User’s Guide 83 Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481 Costa Rica. Contact AT&T…

Page 107 - Compliance Information

Appendix D: Regulatory and Compliance Information Product Regulatory Compliance Warning: To ensure regulatory compliance, you must adhere to the…

Page 108

® Server System SR2520SA User’s Guide • CB Certificate & Report, IEC60950 (report to include all country national deviations) • GS License (Germany) •…

Page 109

® Server System SR2520SA User’s Guide 87 Certifications / Registrations / Declarations • UL Certification (US/Canada) • CE Declaration of Conformity…

Page 110

® Server System SR2520SA User’s Guide C-Tick Mark Australia / New Zealand VCCI Marking (Class A) Japan BSMI Certification Number & Class A Warning…

Page 111

® Server System SR2520SA User’s Guide 89 Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of…

Page 112 - BSMI (Taiwan)

® Server System SR2520SA User’s Guide Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux…

Page 113 - Korean Compliance (RRL)

® Server System SR2520SA User’s Guide 91 Korean Compliance (RRL) Following is the RRL certification information for Korea. English translation of the…

Page 114 - Compliance

® Server System SR2520SA User’s Guide • Add-in boards: must have a printed wiring board flammability rating of minimum UL94V-1. Add-in boards…

Page 115 - Appendix E: Warranty

Appendix E: Warranty Limited Warranty for Intel® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel® chassis…

Page 116 - Limitations of Liability

® Server System SR2520SA User’s Guide This Limited Warranty does not cover damages due to external causes, including accident, problems with…

Page 117 - Returning a Defective Product

® Server System SR2520SA User’s Guide 95 • North America and Latin America To obtain warranty repair for the product, please go to the following Web…

Page 119 - Appendix F: Troubleshooting

Appendix F: Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system. For any issue, first…

Page 120 - First Steps Checklist

® Server System SR2520SA User’s Guide Problems following Initial System Installation Problems that occur at initial system startup are usually caused…

Page 121 - Hardware Diagnostic Testing

® Server System SR2520SA User’s Guide 99 Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem…

Page 122 - Power Light Does Not Light

® Server System SR2520SA User’s Guide • Characters on the screen appear distorted or incorrect. • System cooling fans do not rotate. • Diskette drive…

Page 123

® Server System SR2520SA User’s Guide 101 • Is the video monitor plugged in and turned on? If you are using a switch box, is it switched to the…

Page 124 - Cannot Connect to a Server

® Server System SR2520SA User’s Guide Check the following: • Is the power-on light lit? If not, see “Power Light Does Not Light”. • If your system has…

Page 125 - Problems with Network

® Server System SR2520SA User’s Guide 103 • Make sure you are using the correct and the current drivers. See “Server System References” for a link to…

Page 126

® Server System SR2520SA User’s Guide System Boots when Installing PCI Card System Management features require full-time "standby" power. This means…

Page 127

® Server System SR2520SA User’s Guide 105 include a flickering video display, unexpected system reboots, and the system not responding to user…

Page 128 - BIOS POST Beep Codes

® Server System SR2520SA User’s Guide LED Information The Intel ® Server Board S5000PAL includes LEDs that can aid in troubleshooting your system. A…

Page 129 - Safety Instructions

® Server System SR2520SA User’s Guide 107 Appendix G: Installation/Assembly Safety Instructions English The power supply in this product contains no…

Page 130

® Server System SR2520SA User’s Guide After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and…

Page 131

® Server System SR2520SA User’s Guide 109 Deutsch Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält…

Page 132

® Server System SR2520SA User’s Guide SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten…

Page 133 - Français

® Server System SR2520SA User’s Guide 111 Français Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: •…

Page 134

® Server System SR2520SA User’s Guide CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, suivez les…

Page 135

® Server System SR2520SA User’s Guide 113 Español Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une…

Page 136

® Server System SR2520SA User’s Guide Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del…

Page 137 - Italiano

® Server System SR2520SA User’s Guide 115 Italiano Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar…

Page 138

® Server System SR2520SA User’s Guide Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde…

Page 139

® Server System SR2520SA User’s Guide 117 Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere…

Page 141 - Safety Warnings and Cautions

® Server System SR2520SA User’s Guide 119 Appendix H: Safety Information English Server Safety Information This document applies to Intel ® server…

Page 142 - Equipment Handling Practices

® Server System SR2520SA User’s Guide Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be…

Page 143 - Power and Electrical Warnings

® Server System SR2520SA User’s Guide 121 Power and Electrical Warnings Caution: The power button, indicated by the stand-by power marking, DOES NOT…

Page 144 - Rack Mount Warnings

® Server System SR2520SA User’s Guide System Access Warnings Caution: To avoid personal injury or property damage, the following safety instructions…

Page 145 - Other Hazards

® Server System SR2520SA User’s Guide 123 Electrostatic Discharge (ESD) Caution: ESD can damage disk drives, boards, and other parts. We recommend…

Page 146

® Server System SR2520SA User’s Guide Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel ® Serverplatinen…

Page 147 - Handhabung von Geräten

® Server System SR2520SA User’s Guide 125 Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros…

Page 148 - Hinweis für Netzkabel

® Server System SR2520SA User’s Guide Warnungen zu Netzspannung und Elektrizität Caution: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten…

Page 149 - Warnhinweise für Racks

® Server System SR2520SA User’s Guide 127 Warnhinweise für den Systemzugang Caution: Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor…

Page 150 - Andere Gefahren

® Server System SR2520SA User’s Guide Sie müssen für die gesamte Rack-Einheit einen Netztrennschalter einrichten. Dieser Netztrennschalter muß leicht…

Page 151

® Server System SR2520SA User’s Guide 129 • Prüfen Sie, ob Kabel, Erweiterungskarten sowie weitere Komponenten ordnungsgemäß angebracht sind. •…

Page 152 - Sélection d’un emplacement

® Server System SR2520SA User’s Guide Domaines d’utilisation prévus Ce produit a été testé comme équipement informatique (ITE) et peut être installé…

Page 153

® Server System SR2520SA User’s Guide 131 • Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un…

Page 154

® Server System SR2520SA User’s Guide niveaux dangereux de tension, de courant et d’énergie. Renvoyez-le au fabricant en cas de problème. Lorsque vous…

Page 155

® Server System SR2520SA User’s Guide 133 • Mettez toutes les vis ou autres attaches de côté lorsque vous retirez les panneaux d’accès. Une fois que…

Page 156 - Autres risques

® Server System SR2520SA User’s Guide Décharges électrostatiques (ESD) Attention:Les décharges électrostatiques (ESD) peuvent endommager les lecteurs…

Page 157 - Périphériques laser

® Server System SR2520SA User’s Guide 135 Périphériques laser Attention:Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage…

Page 158 - Seleccién de la ubicación

® Server System SR2520SA User’s Guide Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnología informática (ITE) que…

Page 159 - Manipulacién del equipo

® Server System SR2520SA User’s Guide 137 Manipulacién del equipo Reduzca el riesgo de daños personales o en el equipo: • Respete los requisitos de…

Page 160

® Server System SR2520SA User’s Guide Precaución: Para evitar descargas eléctricas o fuego, revise los cables de alimentación que usará con el…

Page 161 - Descarga electrostática (ESD)

® Server System SR2520SA User’s Guide 139 • Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de…

Page 162 - Otros riesgos

® Server System SR2520SA User’s Guide disponible, protéjase de alguna forma contras las descargas llevando un brazalete antiestático conectado a la…

Page 163

® Server System SR2520SA User’s Guide 141 Periféricos o dispositivos láser Precaución Para evitar el riesgo de la exposición a radiaciones o de daños…

Questions sur Intel SR2520SAXNA

Pas encore de questions sur ce manuel. Posez la première.

Poser une question

Nous répondons à partir du manuel et indiquons la page. La question est publiée sur le site après vérification.

Toutes les questions et réponses ›