Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS Cooling Subsystem
Revision 2.0 25
Intel order number G17455-004
5. Cooling Subsystem
The Intel
®
Server System R1304BTSSFAN, R1304BTLSFAN and R1304BTLSHBN cooling
subsystem consists of three fans, CPU air duct, and PS/electronics bay isolation air baffle.
These components provide the necessary cooling and airflow to the system. A fan on the
processor heatsink is not needed.
To maintain the necessary airflow within the system, the air duct and the top cover must be
properly installed.
Note: The Intel
®
Server Systems R1304BTSSFAN, R1304BTLSFAN and R1304BTLSHBN do
not support redundant cooling. If a fan fails, the system should be powered down as soon as
possible to replace the failed fan blower. The system fans are not hot-swappable.
Figure 10. Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN Fan Module Assembly