10. Close the load plate all the way (see letter “A” in Figure 10). With your finger, push
down on the load plate as shown (see letter “B” in Figure 10). Close the socket lever
and ensure that the load plate tab engages under the socket lever when fully closed
(see letter “C” in Figure 10).
Figure 10. Closing the Load Plate and Socket Lever
Installing the Active Heat Sink
The heat sink has Thermal Interface Material (TIM) located on the bottom of it. Use
caution when you unpack the heat sink so you do not damage the TIM.
1. Make sure the screwdriver slot at the top of each fastener is rotated clockwise so the
screwdriver slot points to the center of the heat sink as shown (see letter “A” in
Figure 11).
2. Align the heat sink with the mounting holes in the server board and lower the
assembly to the board (see letter “B” in Figure 11). The snaps go through the holes in
the server board.
3. Press downward on top of each cap (see letter “C” in Figure 11).
TP01791
A
B
C