Electrical Specifications
56 Datasheet
• SetVID_slow (5mV/µs for V
CC
, 2.5mV/µs for V
SA
/V
CCD
), and
• Slew Rate Decay (downward voltage only and it is a function of the output
capacitance time constant) commands. Table 7-3 includes SVID step sizes and DC
shift ranges. Minimum and maximum voltages must be maintained as shown in
Table 7-10.
The VRM or EVRD used must be capable of regulating its output to the value defined by
the new VID.
Power source characteristics must be ensured to be stable when the supply to the
voltage regulator is stable.
7.1.8.3.2 SetVID Fast Command
The SetVID-fast command contains the target VID in the payload byte. The range of
voltage is defined in the VID table. The VR should ramp to the new VID setting with a
fast slew rate as defined in the slew rate data register; typically, 10 to 20 mV/µs
depending on platform, voltage rail, and the amount of decoupling capacitance.
The SetVID-fast command is preemptive; the VR interrupts its current processes and
moves to the new VID. The SetVID-fast command operates on one VR address at a
time. This command is used in the processor for package C6 fast exit and entry.
7.1.8.3.3 SetVID Slow Command
The SetVID-slow command contains the target VID in the payload byte. The range of
voltage is defined in the VID table. The VR should ramp to the new VID setting with a
“slow” slew rate as defined in the slow slew rate data register. The SetVID_Slow is 1/4
slower than the SetVID_fast slew rate.
The SetVID-slow command is preemptive; that is, the VR interrupts its current
processes and moves to the new VID. This is the instruction used for normal P-state
voltage change. This command is used in the processor for the Intel Enhanced
SpeedStep Technology transitions.
7.1.8.3.4 SetVID Decay Command
The SetVID-Decay command is the slowest of the DVID transitions. It is only used for
VID down transitions. The VR does not control the slew rate; the output voltage
declines with the output load current only.
The SetVID-Decay command is preemptive; that is, the VR interrupts its current
processes and moves to the new VID.
7.1.8.3.5 SVID Power State Functions – SetPS
The processor has three power state functions and these states will be set seamlessly
with the SVID bus using the SetPS command. Based on the power state command, the
SetPS commands send information to the VR controller to configure the VR to improve
efficiency, especially at light loads. For example, typical power states are:
• PS(00h): Represents full power or active mode
• PS(01h): Represents a light load 5A to 20A
• PS(02h): Represents a very light load <5A
The VR may change its configuration to meet the processor power needs with greater
efficiency. For example, it may reduce the number of active phases, transition from
CCM (Continuous Conduction Mode) to DCM (Discontinuous Conduction Mode) mode,
Vue de la page 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 115 116

Commentaires sur ces manuels

Pas de commentaire

Samsung RD040MHXCA Series manuels

Manuels d'utilisation et guides de l'utilisateur pour Climatiseurs à système divisé Samsung RD040MHXCA Series.
Nous fournissons des manuels en pdf 1 Samsung RD040MHXCA Series à télécharger gratuitement par type de document : Manuel d'installation






Plus de produits et de manuels pour Climatiseurs à système divisé Samsung

Modèles Type de document
AS09D2VE Manuel de service   Samsung AS09D2VE Service manual, 55 pages
AQV18NSD Manuel de l'utilisateur   Samsung AQV18NSD User`s manual, 28 pages
AQ09A5(6)MB(D)(E)D Manuel de service   Samsung AQ09A5(6)MB(D)(E)D Service manual, 50 pages
SH07APGAX Spécifications   Samsung SH07APGAX Product specifications, 46 pages
RD080HRXGB Manuel d'installation   Samsung RD080HRXGB Installation manual, 60 pages
AW0719 Spécifications   Samsung AW0719 Product specifications, 18 pages
EH052CAV Manuel de l'utilisateur   Samsung EH052CAV User`s manual, 14 pages
NS Series Spécifications   Samsung NS Series Specifications, 26 pages
SH12ZPGAX Manuel de l'utilisateur   Samsung SH12ZPGAX User manual, 26 pages
AR09HSFSHWKNCV Manuel de l'utilisateur   ar09hsfshwkncv, 4 pages
AQ12B1 Guide d'installation    Samsung AQ12B1 Installation guide, 26 pages
AM 24A1(B1)E12 Spécifications   Samsung AM 24A1(B1)E12 Specifications, 356 pages
AQ07S2GE Spécifications    Samsung AQ07S2GE Specifications, 14 pages
AQV24J Series Instructions d'exploitation   Samsung AQV24J Series Operating instructions, 43 pages
FH070EAV1 Manuel de l'utilisateur   Samsung FH070EAV1 User`s manual [en] , 16 pages
AP50Q1A Manuel de l'utilisateur H Series (Mechanical), 82 pages
AQB12JJWC Instructions d'exploitation   Samsung AQB12JJWC Operating instructions, 107 pages
AQV12P Series Manuel de l'utilisateur   Precauções de Segurança Escolhendo o Local, 4 pages
AQB24J2WC Manuel d'installation   Samsung AQB24J2WC Installation manual, 16 pages
MIM-B18 Manuel d'installation   Samsung MIM-B18 Installation manual, 68 pages