Intel NetStructure MPCBL0001 Manuel d'utilisateur Page 161

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 198
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 160
Intel NetStructure
®
MPCBL0001 Technical Product Specification 161
Serial Over Lan (SOL)
11.7.7 Executing the SOL Client (ipmitool)
To start a SOL console, a user must first connect with the command:
ipmitool -I lanplus -L operator -H <HostIP> -U <UserName> -P <Password> sol
activate
The first argument given in this command line is the host name or IP address of the system on
which ipmitool is running.
The next two arguments are the SOL configured username and password on the SBC. These values
must match the current IPMC settings as set by the SOL configuration reference script.
11.8 Operating Environment
The SOL client utility supports the following operating system environments:
MontaVista* Carrier Grade Linux* (CGE 3.1)