Intel SC5400LXI Fiche technique Page 60

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 104
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 59
Chassis Power Subsystem Intel® Server Chassis SC5400 5U Kit TPS
50 Revision: 1.0
5.4.2 Events
Critical events will cause the power supply to shutdown and latch the LED and SMBAlert signal
no matter what mode the power supply is in; “default” or Intelligent.”
Warning events latch the LED and SMBAlert signal when in “intelligent” mode. If in the “default”
mode, the LED and SMBAlert signal will de-assert as soon as the condition driving the event
clears.
5.4.3 Mean Time Between Failures (MTBF)
The backplane assembly shall have a minimum MTBF at continuous operation of 400,000 hours
at 100% load and 45 C, as calculated by Bellcore RPP, or 1 million hours demonstrated at
100% load and 45 C.