Intel SSR212PP Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Serveurs Intel SSR212PP. Intel SSR212PP User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - PRELIMINARY

PRELIMINARY Intel ® Storage SystemSSR212PP Revision 1.0 Based on EMC AX150 ® Technology User Guide Intel Order Number: D59966-001

Page 2

x Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFigure 46. Storage System Front LEDs . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

86 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 4

Intel Storage System SSR212PP User Guide 8713PRELIMINARYInstalling a Disk ModuleThis procedure describes how to install a disk module in an SSR212PP-S

Page 5

88 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYCAUTIONThe bezel is required for EMI compliance when the storage system is powered u

Page 6

Intel Storage System SSR212PP User Guide 89PRELIMINARYSTEP 4. Install the disk module.CAUTIONThe disk module you install must have a green handle. Do

Page 7

90 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 36. Installing and Locking the Front BezelSAB2935a

Page 8

Intel Storage System SSR212PP User Guide 9114PRELIMINARYConnecting AC Power to aSingle-SP Storage SystemThis section describes how to connect power to

Page 9

92 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 38. Connecting AC Power to an SSR212PPf or SSR212PPi with Two Power Supplies

Page 10

Intel Storage System SSR212PP User Guide 93PRELIMINARYSTEP 3. For each power supply in the storage system, plug the storage system power cord into the

Page 11

94 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 41. Power Button and Rear LEDs on an SSR212PPf with One Power SupplyFIGURE 4

Page 12

Intel Storage System SSR212PP User Guide 9515PRELIMINARYConnecting AC Power to aDual-SP Storage SystemBefore You StartTo complete this procedure, you

Page 13

Intel Storage System SSR212PP User Guide xiPRELIMINARYList of TablesTable 1 iSNS Server Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 14

96 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 3. Plug a storage system power cord into the power connector power supply in th

Page 15

Intel Storage System SSR212PP User Guide 97PRELIMINARYSTEP 5. Plug each storage system power cord into an AC power source as follows (Figure 44):CAUTI

Page 16

98 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 46. Storage System Front LEDsFIGURE 47. SSR212PP2f Storage System Power But

Page 17

Intel Storage System SSR212PP User Guide 9916PRELIMINARYConnecting the ManagementPorts to the LANBefore You StartTo complete this procedure, you need

Page 18

100 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 49. SSR212PP2f Storage System Management LAN Port ConnectionsSTEP 2. If you

Page 19

Intel Storage System SSR212PP User Guide 101PRELIMINARYFIGURE 51. SSR212PP2f Storage System and Switch LAN Connectionsb. If the switch is not hard-zo

Page 20 - Spare 11

102 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 21

Intel Storage System SSR212PP User Guide 10317PRELIMINARYInstalling the NavisphereStorage SystemInitialization UtilityBefore You Start❑ You will need

Page 22

104 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 23

Intel Storage System SSR212PP User Guide 10518PRELIMINARYRunning the NavisphereStorage System InitializationUtility on a FC ConfigurationSTEP 1. Start

Page 24

xii Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 25

106 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 6. Using the information from the completed worksheet in the "Storage Sys

Page 26

Intel Storage System SSR212PP User Guide 10719PRELIMINARYRunning Navisphere StorageSystem Initialization Utilityon a iSCSI ConfigurationSTEP 1. Start t

Page 27

108 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 5. For each iSCSI data port on each SP that you will use, set the following po

Page 28

Intel Storage System SSR212PP User Guide 109PRELIMINARYIf you entered an SP IP address for the first time or changed an SP IP address, the utility reb

Page 29

110 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 30

Intel Storage System SSR212PP User Guide 11120PRELIMINARYShutting the StorageSystem DownYou can shut down the storage system with Navisphere Express o

Page 31

112 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 32

Intel Storage System SSR212PP User Guide 11321PRELIMINARYConnecting a Fibre ChannelStorage System to the ServerUse optical cables to connect storage s

Page 33

114 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY For dual-SP systems, connect either FE port on SP A to one switch and either FE p

Page 34

Intel Storage System SSR212PP User Guide 115PRELIMINARYFIGURE 55. SSR212PP2f Front End (FE) and Optical Cable ConnectorsSTEP 3. For each switch port

Page 35

Intel Storage System SSR212PP User Guide xiiiPRELIMINARYPrefaceAbout this ManualThank you for purchasing and using the Intel¤ Storage System SSR212PP.

Page 36

116 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 57. Sample Hard-zoned Switch Connections to an SSR212PP2f Storage SystemSTE

Page 37

Intel Storage System SSR212PP User Guide 11722PRELIMINARYConnecting iSCSI Ports tothe ServerConnect iSCSI data ports on iSCSI storage systems directly

Page 38 - Disadvantages

118 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 58. Connecting SSR212PPi iSCSI Ports Directly to a ServerFIGURE 59. Connec

Page 39

Intel Storage System SSR212PP User Guide 119PRELIMINARYFIGURE 60. Figure 36 Connecting the SSR212PPi and Server iSCSI Ports to a LANFIGURE 61. Figur

Page 40

120 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYConfiguring iSCSI Initiators for Linux or Windows Configurations without iSNSIf you a

Page 41 - Sample IP addresses

Intel Storage System SSR212PP User Guide 121PRELIMINARYthe storage system and the server, check Mutual CHAP if you want mutual CHAP enabled on the ini

Page 42 - Servers)

122 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYCAUTIONThe Linux iSCSI driver gives the same name to all NICs in a server. This nam

Page 43 - Initiator Servers)

Intel Storage System SSR212PP User Guide 123PRELIMINARYTo stop the iSCSI service, enter /etc/init.d/iscsi stop.STEP 4. Set the run levels for the iSCS

Page 44

124 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYi. Enable timestamps, set the execution throttle to 256, and uncheck immediate data

Page 45

Intel Storage System SSR212PP User Guide 125PRELIMINARYCAUTIONThe Microsoft iSCSI Initiator gives the same name to all NICs in a server. This name ide

Page 46

xiv Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 47 - (Single-Initiator Server)

126 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYConfiguring HBA initiators on Windows servers for iSNSUse the use QLogic SANsurfer p

Page 48 - (Multiple-Initiator Servers)

Intel Storage System SSR212PP User Guide 12723PRELIMINARYRegistering the Server withthe Storage SystemIf the storage system is connected to a Linux se

Page 49

128 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYTo each storage system, the utility sends the server s name and IP address. Once th

Page 50 - Dedicated

Intel Storage System SSR212PP User Guide 12924PRELIMINARYConfiguring a NewStorage SystemRead this section if you are configuring a new storage system.

Page 51

130 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYon these disks is reserved or preloaded with system data, and as a result, is not a

Page 52

Intel Storage System SSR212PP User Guide 131PRELIMINARY For NICs:/etc/init.d/PowerPath stop/etc /init.d/iscsi stop/etc /init.d/iscsi start/etc/ini.d/

Page 53

132 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYv. Click on each virtual disk to display a list of :paths to the disk, and verify t

Page 54

Intel Storage System SSR212PP User Guide 13325PRELIMINARYConfiguring an ExistingStorage SystemRead this section if you are configuring an existing stor

Page 55

134 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYTo send data to or receive data from the virtual disks, you must assign the virtual

Page 56

Intel Storage System SSR212PP User Guide 135PRELIMINARYd. If the virtual disk is connected to a server running Windows Server 2003, reboot the server.

Page 57

Intel Storage System SSR212PP User Guide 11PRELIMINARYPlanning Your Fibre ChannelStorage SystemConfigurationThis document is written for administrators

Page 58

136 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 59

Intel Storage System SSR212PP User Guide 13726PRELIMINARYSetting up CHAP Security foriSCSI Storage SystemsChallenge Handshake Authentication Protocol

Page 60

138 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYTo set up mutual CHAP you must first configure advanced initiator CHAP. On each se

Page 61

Intel Storage System SSR212PP User Guide 139PRELIMINARYv. Select the IP address of the Inactive target and click Remove. All targets for the storage s

Page 62

140 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 10. Enable basic CHAP on the storage systema. Open Navisphere Express on the s

Page 63

Intel Storage System SSR212PP User Guide 141PRELIMINARYYou will also enter this secret for the server initiators.You can specify the secret in ASCII o

Page 64

142 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 10. Click View mutual CHAP credentials and confirm that the new CHAP entry exi

Page 65

Intel Storage System SSR212PP User Guide 143PRELIMINARY Discover iSCSI targets using this iSNS Server discovers the specified IP address of the iSNS

Page 66

144 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYConfiguring Basic Chap on a Linux Server with NICsCAUTIONCHAP security must be enabl

Page 67

Intel Storage System SSR212PP User Guide 145PRELIMINARY# Password=welcome# or# OutgoingUsername=john# OutgoingPassword=welcome## The "OutgoingUse

Page 68

2 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYStorage System Management PortsThe storage system can have two management ports, one

Page 69

146 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY# IncomingPassword=foo# TargetName Specific Settings# ----------------------------#

Page 70

Intel Storage System SSR212PP User Guide 147PRELIMINARY# ActiveTimeout=15## In the above scenario, the Subnet specific settingwill take effect.# If th

Page 71

148 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY/etc/init.d/iscsi startSTEP 5.Run the Navisphere Server Utility to update the stora

Page 72

Intel Storage System SSR212PP User Guide 149PRELIMINARYConfiguring Advanced or Mutual CHAP on a Windows Server with NICsCAUTIONCHAP security must be en

Page 73

150 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYIf CHAP authentication is enabled on all target ports on a storage system, you cann

Page 74

Intel Storage System SSR212PP User Guide 151PRELIMINARYConfiguring Advanced or Mutual CHAP on a Server with iSCSI HBAsSTEP 1. Open the SANsurfer softwa

Page 75

152 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYConfiguring Advanced or Mutual CHAP on a Linux Server with NICsCAUTIONCHAP security

Page 76

Intel Storage System SSR212PP User Guide 153PRELIMINARYUsername=bettyPassword=bienvenueWhen you have configured advanced CHAP for each NIC initiator i

Page 77

154 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 7. In Step 2 on the screen, enter a CHAP username. This name must match whatev

Page 78

Intel Storage System SSR212PP User Guide 15527PRELIMINARYPreparing Virtual Disks toReceive DataBefore a server can send data to a virtual disk,  Linu

Page 79

Intel Storage System SSR212PP User Guide 3PRELIMINARYFibre Channel Switch InformationIf your configuration will use one or more Fibre Channel switches

Page 80

156 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYmkfs /dev/device_namepartition_numberwhere device_name is the pseudo device name fo

Page 81 - ABLE 2. Language Locale ID

Intel Storage System SSR212PP User Guide 157PRELIMINARYPreparing Virtual Disks for WindowsMicrosoft iSCSI Software Initiator does not support dynamic

Page 82

158 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYd. If you want a logical drive on an extended partition, create it:i. Right-click t

Page 83

Intel Storage System SSR212PP User Guide 15928PRELIMINARYVerifying the FailoverConfigurationBefore you store data on virtual disks, use the procedure i

Page 84

160 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYb. Scan for hardware changes:i. On the desktop, right-click My Computer and click M

Page 85

Intel Storage System SSR212PP User Guide 161PRELIMINARYVerifying the Failover Configuration for a Windows ServerSTEP 1. If you connected a new server t

Page 86

162 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYVerifying the Failover Configuration for a Linux ServerSTEP 1. If you connected a ne

Page 87

Intel Storage System SSR212PP User Guide 16329PRELIMINARYRunning NavisphereExpressSTEP 1. Open an Internet browser on the management host.STEP 2. Ente

Page 88

164 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 89

Intel Storage System SSR212PP User Guide 16530PRELIMINARYRunning the NavisphereServer UtilityThis procedure provides server-specific instructions for

Page 90

4 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSample Switch Information WorksheetA sample switch worksheet section follows. It desc

Page 91 - EMC2794a

166 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYIf the utility is already running, it does not automatically perform a scan, and yo

Page 92 - HW S/N XXX 000NNNNNNNN

Intel Storage System SSR212PP User Guide 16731PRELIMINARYApplying iSCSI Data PortAddresses to the SPAssemblyPerform the following procedure after repl

Page 93

168 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 94

Intel Storage System SSR212PP User Guide 16932PRELIMINARYRestoring a StorageProcessor Boot ImageThis procedure explains how to restore a storage proce

Page 95 - AF000637

170 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSecondary boot diskThe higher numbered disk in the mirrored boot pair for an SP. Fo

Page 96

Intel Storage System SSR212PP User Guide 171PRELIMINARYFIGURE 62. Connecting a Server or Laptop COM Port to an SP Service PortSTEP 3. Start a HyperTe

Page 97

172 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYThe easiest way to reset the SP is to unplug and then plug in the line cord to the

Page 98

Intel Storage System SSR212PP User Guide 173PRELIMINARYFIGURE 64. Screen Shot: Interrupting the Alphabetic TestThe screen displays the following mess

Page 99

174 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 65. Screen Shot: Booting from the Utilities PartitionSTEP 7. Press Enter to

Page 100

Intel Storage System SSR212PP User Guide 175PRELIMINARYFIGURE 66. Screen Shot: Toolkit Main MenuSTEP 8. Select Install Images from the menu. The soft

Page 101

Intel Storage System SSR212PP User Guide 5PRELIMINARYCompleting the Switch Information WorksheetOn the worksheet, for each switch port, indicate the S

Page 102

176 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 67. Screen Shot: Select Images to InstallSTEP 9. Select the recovery image

Page 103

Intel Storage System SSR212PP User Guide 177PRELIMINARYFIGURE 68. Screen Shot: Copying the Boot ImageFor SSR212PP2f or SSR212PPf (Fibre Channel) syst

Page 104 - SAB2935a

178 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 19. Disconnect the service serial cable and adapter (if present) from the SP a

Page 105 - Single-SP Storage System

Intel Storage System SSR212PP User Guide 17933PRELIMINARYUsing FTP to Obtain andStore an SP Boot ImageThis procedure explains how to load and use an S

Page 106 - Supplies

180 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 3. Enter n. The software displays the Toolkit Screen Main Menu.STEP 4. Select

Page 107

Intel Storage System SSR212PP User Guide 181PRELIMINARYSTEP 9. At the login prompt, enter the username clariion (if not already present) and the passw

Page 108

182 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 109 - Dual-SP Storage System

ii Intel Storage System SSR212PP User Guide Revision 1.0 PRELIMINARY Disclaimers Information in this document is provided in connection with Intel®

Page 110

6 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYStorage System Disk InformationThis section defines storage system disk information.

Page 111

Intel Storage System SSR212PP User Guide 7PRELIMINARYIf your system has two SPs, you should create at least two disk pools, since the software assigns

Page 112

8 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYDisk pool capacity (Gbytes)To calculate the size of a RAID 5 disk pool, multiply the

Page 113 - LAN port

Intel Storage System SSR212PP User Guide 92PRELIMINARYInstalling a Fibre ChannelStorage SystemThis procedure describes the process of connecting an SS

Page 114

10 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYstorage processor (SP)A printed-circuit board with processors, memory modules, and c

Page 115

Intel Storage System SSR212PP User Guide 11PRELIMINARYcan also be the server. For supported hosts and browsers, refer to Tested Hardware and OS List (

Page 116

12 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYCAUTIONThe UPS ships with the battery cable disconnected. Be sure to connect this ca

Page 117

Intel Storage System SSR212PP User Guide 13PRELIMINARYFIGURE 2. SSR212PPf Storage System Rear Lights (LEDs)FIGURE 3. SSR212PP2f Storage System Rear

Page 118

14 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 16. Register the server with the storage system by following Procedure 23, &quo

Page 119

Intel Storage System SSR212PP User Guide 153PRELIMINARYPlanning Your iSCSI StorageSystem ConfigurationThis document is written for administrators who a

Page 120

Intel Storage System SSR212PP User Guide iii PRELIMINARY Safety Information Important Safety Instructions Read all caution and safety statements in t

Page 121

16 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYIntroductionSSR212PP-Series iSCSI storage systems connect to servers through Interne

Page 122

Intel Storage System SSR212PP User Guide 17PRELIMINARYthe initiators. To increase the level of security, you can also set up mutual CHAP authenticatio

Page 123

18 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYiSCSI Configuration RulesRefer to this section as you plan your iSCSI environment wit

Page 124

Intel Storage System SSR212PP User Guide 19PRELIMINARY You can connect up to four iSCSI HBAs or 4 NIC initiators (2 two-port NICs or 4 one-port NICs)

Page 125

20 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYAdministration WorksheetThe accompanying Administration Worksheet contains the follo

Page 126

Intel Storage System SSR212PP User Guide 21PRELIMINARY Class A: 10.0.0.0 - 10.255.255.255 Class B: 172.16.0.0 - 172.31.255.255 Class C: 192.168.0.0

Page 127

22 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSubnet Mask for iSCSI Initiator PortThe subnet mask for the LAN to which the initiat

Page 128

Intel Storage System SSR212PP User Guide 23PRELIMINARYSample SSR212PP2i and SSR212PPi ConfigurationsThe following examples show viable iSCSI configurat

Page 129

24 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSSR212PPi Directly Connected to One ServerFigure 5 shows one server, with two iSCSI

Page 130

Intel Storage System SSR212PP User Guide 25PRELIMINARYSSR212PPi Directly Connected to Two ServersFigure 6 shows two servers, each with an iSCSI initia

Page 131

iv Intel Storage System SSR212PP User Guide Revision 1.0 PRELIMINARY Warnings Heed safety instructions: Before working with your server product, whe

Page 132

26 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 7. SSR212PP2i (Dual SP) Directly Connected to One ServerSample IP AddressesP

Page 133

Intel Storage System SSR212PP User Guide 27PRELIMINARYFIGURE 8. SSR212PP2i (Dual SP) Directly Connected to Two ServersSample IP addressesPort IP addr

Page 134

28 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 9. SSR212PP2i (Dual SP) Directly Connected to Four ServersSample IP addresse

Page 135

Intel Storage System SSR212PP User Guide 29PRELIMINARYFIGURE 10. SSR212PPi (Single SP) Connected to a Dedicated NetworkSample IP addressesPort IP add

Page 136

30 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 11. SSR212PPi On a Dedicated LAN with Redundant PathsSample IP addressesPort

Page 137

Intel Storage System SSR212PP User Guide 31PRELIMINARYFIGURE 12. Network-Connect SSR212PP2i (Dual SP, Dedicated LAN)Sample IP addressesPort IP addres

Page 138

32 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSSR212PP2i Connected to a Dedicated iSCSI Network (Multiple-Initiator Servers)Figure

Page 139

Intel Storage System SSR212PP User Guide 33PRELIMINARY Using two storage processors improves overall storage system performance. Connection to each

Page 140

34 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYManagement port IP addresses should match the corporate network scheme.Advantages L

Page 141

Intel Storage System SSR212PP User Guide 35PRELIMINARYSample IP addressesPort IP address Subnet mask GatewayStorage Processor A management port 172.31

Page 142

Intel Storage System SSR212PP User Guide v PRELIMINARY Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 143

36 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYThis configuration requires a NIC connection; iSCSI HBAs qualified on SSR212PP-Serie

Page 144

Intel Storage System SSR212PP User Guide 37PRELIMINARYDisadvantages Reduced access for remote management: To perform management tasks, you must be co

Page 145

38 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSample IP addressesPort IP address Subnet mask GatewayStorage Processor A management

Page 146

Intel Storage System SSR212PP User Guide 39PRELIMINARYFIGURE 18. SSR212PPi/SSR212PP2i (Single SP) to a Shared Single iSCSI NICIP addresses in a share

Page 147

40 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYStorage System Disk InformationThis section defines storage system disk information.

Page 148

Intel Storage System SSR212PP User Guide 41PRELIMINARYNumber (1-6 or spare)You must create at least one disk pool for virtual disks. You can create up

Page 149

42 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYDisk pool capacity (Gbytes)To calculate the size of a RAID 5 disk pool, multiply the

Page 150

Intel Storage System SSR212PP User Guide 43PRELIMINARYWhat is Microsoft iSNS?Microsoft Internet Storage Naming Service (iSNS) is an option that applie

Page 151

44 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 19. Sample iSNS Storage ConfigurationThe storage system actively communicates

Page 152

Intel Storage System SSR212PP User Guide 45PRELIMINARYiSNS Server WorksheetEnter the public IP address and name of your network s primary iSNS server

Page 153

vi Intel Storage System SSR212PP User Guide Revision 1.0 PRELIMINARY Installing or Updating the HBA Driver . . . . . . . . . . . . . . . . . . . . .

Page 154

46 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYWhat is CHAP?Challenge Handshake Authentication Protocol (CHAP) is an optional iSCSI

Page 155

Intel Storage System SSR212PP User Guide 47PRELIMINARYiSCSI CHAP Authentication WorksheetsIf the storage system is on a private LAN, you can elect not

Page 156

48 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYInitiator nameThe initiator name is a predefined name that usually begins with iqn (

Page 157

Intel Storage System SSR212PP User Guide 49PRELIMINARYCHAP secret (password)For ASCII, the valid range is 12 to 16 printable characters. For hexadecim

Page 158

50 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 159

Intel Storage System SSR212PP User Guide 514PRELIMINARYInstalling an iSCSIStorage SystemThis procedure describes the process of connecting an SSR212PP

Page 160

52 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYfield-replaceable unit (FRU)A storage system component that you can add to your stora

Page 161

Intel Storage System SSR212PP User Guide 53PRELIMINARY Static IP address for each SP in the storage system. Subnet mask for the LAN to which you wil

Page 162

54 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYThe Installation ProcedureSTEP 1. Install the NICs or iSCSI HBAs in the server. See

Page 163

Intel Storage System SSR212PP User Guide 55PRELIMINARYYou may receive a second power supply that looks slightly different from the original, and/or di

Page 164

Intel Storage System SSR212PP User Guide vii PRELIMINARY Running the Navisphere Server Utility on a Linux Server . . . . . . . . . . . . . . . . . .

Page 165

56 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 21. SSR212PPi Storage System Rear Lights (LEDs)b. The amber system Fault lig

Page 166

Intel Storage System SSR212PP User Guide 57PRELIMINARYSTEP 18. Prepare virtual disks to receive data. Use Procedure 27, "Preparing Virtual Disks

Page 167

58 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 168

Intel Storage System SSR212PP User Guide 595PRELIMINARYHandling Field-ReplaceableUnits (FRU)This section describes the precautions that you must take

Page 169 - Preparing Virtual Disks to

60 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYWithout an ESD KitWhen an ESD kit is not available, use the following procedures to

Page 170

Intel Storage System SSR212PP User Guide 616PRELIMINARYInstalling HBAs in theServerFor the server to communicate with the storage system Fibre Channel

Page 171

62 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYInstalling or Updating the HBA DriverThe server must run a supported HBA driver and

Page 172

Intel Storage System SSR212PP User Guide 637PRELIMINARYInstalling PowerPathon the ServerPowerPath manages the I/O paths between the server and storage

Page 173

64 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 4. In the Choose Language Setup window, select the language you want for this i

Page 174

Intel Storage System SSR212PP User Guide 65PRELIMINARY/lib/modules/‘uname -r‘/drivers/addon/hbaDriverwhere uname -r is the string returned to the cons

Page 175

viii Intel Storage System SSR212PP User Guide Revision 1.0 PRELIMINARY

Page 176

66 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYiv. Run ls -l /boot and look at the line with initrd -> to determine which initrd

Page 177

Intel Storage System SSR212PP User Guide 67PRELIMINARYv. Run ls -l /boot to determine which initrd and vmlinuz files are used for the kernel version.

Page 178

68 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYSTEP 9. Change to the LINUX directory for your kernel and revision of PowerPath that

Page 179

Intel Storage System SSR212PP User Guide 69PRELIMINARYIf you loaded the HBA, NIC or iSCSI HBA driver as a module (not as a static kernel driver), use

Page 180

70 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYwhere driver_module is the name of theHBA drivermodule used to access the storage sy

Page 181

Intel Storage System SSR212PP User Guide 718PRELIMINARYInstalling PowerPath iSCI forWindows 2003 ServerInstalling PowerPath iSCSI for Windows 2003 Ser

Page 182

72 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYIf you do not know whether your Windows 2003 Server is 32-bit or 64-bit, right-click

Page 183

Intel Storage System SSR212PP User Guide 73PRELIMINARYCAUTIONThis procedure requires that you reboot the server that you want to upgrade.Before You St

Page 184

74 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 185 - (SP A only)

Intel Storage System SSR212PP User Guide 759PRELIMINARYInstalling the NavisphereServer UtilityRead this section for all configurations.You must instal

Page 186

Intel Storage System SSR212PP User Guide ixPRELIMINARYList of FiguresFigure 1. HBA and Port Connectivity . . . . . . . . . . . . . . . . . . . . . .

Page 187

76 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYInstalling the Navisphere Server Utility on a Linux ServerSTEP 1. Insert the SSR212P

Page 188

Intel Storage System SSR212PP User Guide 7710PRELIMINARYUnpacking the SSR212PP-Series Storage SystemCAUTIONThe equipment is heavy and should be instal

Page 189

78 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 24. Locating the Storage System Serial Number HW S/N XXX 000NNNNNNNNEMC3263

Page 190

Intel Storage System SSR212PP User Guide 7911PRELIMINARYInstalling the SSR212PP-Series Storage SystemRead this section if you are installing a new sto

Page 191

80 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 25. Installing Mounting Rails in a 19-inch NEMA CabinetSTEP 2. If the front

Page 192

Intel Storage System SSR212PP User Guide 81PRELIMINARYinstall the unit into a rack without a mechanical lift and/or help from another person.STEP 4. F

Page 193

82 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARY

Page 194

Intel Storage System SSR212PP User Guide 8312PRELIMINARYInstalling a SecondPower SupplyRead this section if you received a second power supply for you

Page 195

84 Intel Storage System SSR212PP User GuideRevision 1.0PRELIMINARYFIGURE 30. Installing a Second Power SupplySTEP 4. Pull the wire retention bail out

Page 196

Intel Storage System SSR212PP User Guide 85PRELIMINARYFIGURE 32. Power button and Indicators for an SSR212PPf with Two Power SuppliesPower On/Off But

Commentaires sur ces manuels

Pas de commentaire